DCL![]()
DC Voltage Converters
Datasheet (PDF 82KB)
User
Manual (Multilanguage) (PDF 2.93MB)
CE Certificate (PDF 32KB)
|
The DCL extends the functionality of the DCS by adding excess energy management functionality that provides usable energy that would normally be wasted because the battery cannot accept the extra solar energy. With DCL it is possible to charge a second battery with excess energy. This is widely used in mobile-homes and boats which often have a battery for the solar system and a second battery for starting the engine. Another typical application is to power a small fan for air exchange on a boat powered only with excess energy. Only your imagination limits the number of possible applications.
| TYPE | DCS | ||||||
|---|---|---|---|---|---|---|---|
| Nominal Voltage | 12V | ||||||
| Output Voltage
and |
1.5v | 3.0v | 4.5v | 6.0v | 9.0v | 12.0v | 13.6v* |
| Maximum Output
Current |
250mA | 300mA | 400mA | 450mA | 650mA | 1000mA | 2000mA |
| Self consumption | 6mA | ||||||
| Diameter Wire |
0.75 to 16mm2 | ||||||
| Temperature range | -20 to +50°C | ||||||
| Max. power dissipation |
4W | ||||||
| Dimensions | 100 x 80 x 34mm | ||||||
| Weight | 125gr | ||||||
| Additional Data DCL | |||||||
| Nominal Voltage 2nd Battery | 12V | ||||||
| Float voltage 2nd Battery | 13.4V | ||||||
| Max. charging current@13.4V | 2A | ||||||
* The 13.6V output voltage can only be got when the input voltage is higher than 13.6V