CM series (4 – 10 A)
CA series (6 – 14 A)
CIS series (5 – 20 A)
CIS-N series (5 – 20 A)
CIS-LED (5 A)
CML series (5 – 20 A)
Dingo (20 A)
CX series (10 – 40 A)
CXN series (10 – 40 A)
PL series (20 – 60 A)
SPS series (100 – 300 A)
CIS-MPPT (20A)
| Type | CML 05 CML 08 CML 10 CML 15 CML 20 |
|---|---|
| System voltage | 12/24 V auto recognition |
| Max. charge/load current | 5 A 8 A 10 A 15 A 20 A |
| Float charge | 13.7/27.4 V (25 °C) |
| Boost charge | 14.4 /28.8 V (25 °C), 2 Std. activation: battery voltage <12.3/24.6 V |
| Equalization | 14.8/29.6 V (25 °C), 2 Std. activation: battery voltage <12.1/24.2 V |
| Deep discharge protection: State of charge dependent Voltage dependent Reconnect level |
11.4 – 11.9 V / 22.8 – 23.8 V 11.0/22.0 V 12.8/25.6 V |
| Overvoltage protection | 15.5/31.0 V |
| Undervoltage protection | 10.5/21.0 V |
| Max. panel voltage (Overvoltage protection by varistor) | 30 V in 12 V system 50 V in 24 V system |
| Temperature compensation (Charge voltage) | −25 mV/K at 12V −50 mV/K at 24V |
| Max. self consumption | < 4 mA |
| Grounding | positive grounding possible |
| Ambient temperature | −40 to +50 °C |
| Max. height | 4,000 m above sea level |
| Battery type | lead acid (GEL, AGM, flooded) |
| Wire cross section | < 16 mm2 |
| Weight | 160 g |
| Dimensions (W xH x D) | 80 x 100 x 32 mm |
| Type of protection | IP22 |